ChipFind - документация

Электронный компонент: ARX2412

Скачать:  PDF   ZIP
eroflex Circuit T
echnology
Data Bus Modules For The Future SCD2412 REV C 10/19/98
Features
PERFORMS FUNCTIONS COMMON TO MIL-STD-1553
ENCODE
DECODE
ADDRESS RECOGNITION
THREE STATE PARALLEL I/O
SELF TEST CAPABILITY
MIL-PRF-38534 COMPLIANT CIRCUITS AVAILABLE
SMALL SIZE REPLACEMENT FOR DDC8937 MODEL NUMBER
5V DC OPERATION
FULL MILITARY (-55C TO +125C) TEMPERATURE RANGE
1
General Description
The Aeroflex Circuit Technology Model ARX2412 Manchester Converter is a self contained, 48pin,
triple-in-line hybrid package designed to perform: encode, decode, logic and control functions in a
MIL-STD-1553, A and B multiplex data system. It Provides the necessary interface between transceivers and
a three state parallel 16 bit bus of the protocol logic section of a subsystem remote terminal or controller.
Figure 1 FUNCTIONAL BLOCK
DIAGRAM
Data Terminal Manchester Converter
ARX2412
for MIL-STD-1553
BITS 5-15
BITS 0-4
BITS 0-4
CLK
3 STATE ENABLE
AND BUFFER
3 STATE LATCHES
3 STATE OUT
3 STATE IN
AND BUFFER
3 STATE LATCHES
3 STATE ENABLE
PARALLEL
SHIFT
TO SERIAL
REGISTER
RESET
SERIAL
CLOCK
ENABLE
SERIAL TO
SHIFT
PARALLEL
REGISTER
SERIAL
CLOCK
DATA
SERIAL
OUT
CLK
IN
VALID
WORD
DECODER
IN
RX DATA
CLK1
SYNC
RECEIVER
SECTION
BUSY
OUTPUT
RX DATA
12MHZ
CLOCK 1
INPUT
12MHZ
CLOCK 2
INPUT
12MHZ
CLOCK
SELECT
CLOCK
LOGIC
SELECT
CLK
BUSY
ENCODER
IN
SYNC
ENABLE
OUT
OUT
CLK
ADDRESS
REGISTER
RECOGNITION
VALID
REGISTER
ADDRESS
VALID
POC POWER ON CLEAR
RECEIVER SYNC TYPE
BUSY RECEIVE
OWN ADDRESS 5 BITS
COMMAND SYNC CLEAR
(ADDRESS REGISTER CLEAR)
VU INT
(VALID ADDRESS)
SACK
(SYSTEM ACKNOMLEDGE)
TO / FROM 16 BIT PARALLEL BUS
BITS DB0 - DB15
OSEL
(OUTPUT SELECT)
TRANSMITTER BUSY
SYNC SELECT
ENCODER ENABLE
VALID WORD
F
I
E
I
D
C
E
R T
A
E
R
O
F
L E
X L A
B
S
I
N
C
.
ISO
9001
TRANSMITTER
SECTION
TX DATA
TX DATA
DATA
5 BITS
MSB - LSB
16 BITS
B0-B4, MSB-LSB
SERIAL
VALID
REGISTER
WORD
Aeroflex Circuit Technology
SCD2412 REV C 10/19/98 Plainview NY (516) 694-6700
2
Theory of Operation
This section provides a detailed functional
description of the MIL-STD-1553A/B
Command/Response Manchester II converter
(hereinafter referred to as Converter) and is
intended for use with the timing diagrams shown
in Figures 2 and 3.
GENERAL
POWER ON CLEAR (POC): A logic "0" input
applied at turn-on initializes all of the internal
logic. This signal clears the encoder/decoder
internal counters and initializes the encoder and
decoder functions. This can also be used to abort
a transmission.
DECODER OPERATION
An seen in Figure 1, Functional Block Diagram,
the converter interfaces directly with the
MIL-STD-1553 transceiver by mans of four lines,
namely Tx DATA, Tx DATA, Rx DATA, and Rx
DATA. In the decode mode of operation, the
converter normally needs logic lows (OFF Mode)
on Rx DATA and Rx DATA. Whenever the
MIL-STD-1553 data bus is active, the
MIL-STD-1553 transceiver will output signals that
are similar to those illustrated in Figure 2 (Rx
DATA and Rx DATA) to the converter.
Approximately 5sec after the converter has
detected the first transition change in, the Rx
DATA input line, the Received Busy output line will
activate from a low to high state and remain high
for 16sec. During this period, the internal
Encoder/Decoder is shifting serial data out and
the information is being clocked into an internal 16
bit serial to parallel shift register. The Receiver
Busy line will go low after 16sec, and will remain
low for 4sec if another 20 bit word immediately
follows the first word. The second word will cause
Receiver Busy to go high for another 16sec time
interval, This sequence continues until no
additional information is to be processed.
At approximately the same time as the first
Receiver Busy low to high transition, the Receiver
Sync Type line will go high if a command or status
sync field is detected by the internal decoder. It
too will remain high for 16sec. If a data sync field
is detected by the decoder, the Receiver Sync
Type line will remain in the low state. During the
receiver busy time the decoder shifts serial data
out to the serial to parallel shift register,
regardless of whether the data is valid or not.
However, the stored data is not shifted into the
3-state output buffer unless a Valid Word
indication occurs. This signal is designated Valid
Word. Valid Word performs three functions within
the converter: strobes the 16 bit parallel word into
the 3-state output buffer, strobes the address
recognition function and indicates to the
subsystem user that a valid 16 bit word is now
ready to be processed. A high to low transition on
the Valid Word line will indicate the receipt of a
Valid Word.
The first five bits of a 16 bit command word
represent the terminal address. The bits are
decoded, shifted through the serial to parallel shift
register and compared to the five lines in the
address recognition register (own address, B0
(MSB) thru B4). If a command word is received,
and the own address lines and decoder remote
terminal address bits correspond, and Valid Word
occurs, then a Valid Address Signal (VU INT) will
Specifications
Parameter
Units
Value
External Clock
Oscillator Type (12MHz)
TTL
As per MIL-STD-1553 A/B long and short term
Power Supply Characteristics
Voltage Input
Current
Vdc
mA
+5.0 5%
200 max
Thermal Characteristics
Operating Current
Storage Current
C
C
-55 to +125 (Case Temperature)
-55 to +150
Physical Characteristics
Weight
Size
oz
in.
0.7 (20g) approx.
1.7 x 1.1 x 0.2 (43 x 28 x 5.1 mm)
Aeroflex Circuit Technology
SCD2412 REV C 10/19/98 Plainview NY (516) 694-6700
3
occur going from a logic "1" to logic "0". This signal
transitions at the same time as Valid Word. Upon
detecting a Valid Word output, the user subsystem
must respond with a signal called System
Acknowledge (SACK). A high to low input to the
converter will set both Valid Word and VU INT (if
occurred) to their original high states. These two
outputs are then ready to analyze the next received
20 bit word. At the same time, SACK will enable the
output 3-state buffer for data readout on the 16
parallel data lines. The user subsystem has up to
20sec to process the data before the next 20 bit
word is ready to be latched in the output buffer. A
return to the high state on SACK will cause the
3-state output buffer to return to the high impedance
state, completing the conversion of one 20 bit word.
The command sync clear input signal is required to
initialize the converter internal logic, set by
detection of command or status sync. It also resets
Valid Word logic. This input signal must be applied
each time a receiver sync type transitions, low to
high, occurs but must not occur until the Valid Word
transitions high to low. Under certain
circumstances, valid address transition may not
occur after a valid sync field is recognized.
ENCODER OPERATION
In the encode mode of operation (Figure 3), the
converter normally provides logic highs (off mode)
on Tx DATA and Tx DATA. These two signal lines
provide output data in complementary serial phase
modulated format to the MIL-STD-1553 transceiver
during a transmission. To effect a transmission from
the converter, the sequence of events is to first load
16 bit parallel data into the 3-state input buffer. This
is achieved by the presentation of an input pulse of
logic zero on the Output Select (OSEL) line. Data to
the converter must be stable when the OSEL
occurs. When the XMTR busy signal goes from low
to high, the OSEL may be activated to load the next
16 bit word in preparation for transmission.
Next, the user subsystem must bring the Encoder
Enable line high to initiate a transmission. Encoder
Enable can be conveniently triggered from the
leading or trailing edge of OSEL but must remain
high for 1.0sec after the trailing edge of OSEL.
If the Encoder Enable line is allowed to remain high,
successive transmissions will result. The transmitter
busy line will go high for 16sec every time a 20 bit
word is processed through the internal Encoder.
Transmitter Busy indicates to the user subsystem
that control logic is shifting data from the parallel to
serial data buffer to the bi-phase encoder during a
transmit cycle. To terminate a transmission, the
Encoder Enable line must be brought low on or
before the high to low transition of the current
transmitter busy signal.
The remaining signal that is required to make the
converter encoder operate properly is the Sync
Select input signal. Sync Select is an input from the
user subsystem for the purpose of setting the
appropriate sync field polarity to correspond with
the word to be transmitted. A high on this line will
create a command or status sync field, and a low
will result in a data sync field. Initially it should be
set to a Logic "1" before the encoder enable line is
set high, and remain high no later than the high to
low transition of the transmitter busy signal.
Appplication and Operation
Information
General
LOGIC COMPATIBILITY
Direct logic compatibility exists with transceiver
types which have logical low receiver outputs at
times when the bus is not active, such as Models
ARX3402/4402 and ARX3411/4411. Use with
logical high receiver output devices, such as
Aeroflex Models ARX3231/3232 or ARX3404/4404
will necessitate utilization of inverters between
transceiver RX outputs and Model ARX2412 RX
inputs.
POWER ON CLEAR (POC)
A low on this input line resets all internal registers
and initializes the Manchester Converter for
transmission of complete messages.
DATA I/O (DB0-DB15)
The 16 bits of input and output are three state lines.
Impedance of the receiver section latches is high
during transmit cycle. Latched data can be retained
for up to 20sec. during input of next data word.
TERMINAL ADDRESS LINES (B0-B4)
Addressing the 5 bit address lines is done by hard
wiring. Internal pull up resistors allow logic "1" lines
to be open circuited. Logic "0" lines must be tied to
ground. When a valid command word incorporating
the proper address is received at the input it will
cause VU INT to go low.
Aeroflex Circuit Technology
SCD2412 REV C 10/19/98 Plainview NY (516) 694-6700
4
SELF TEST COMPATABILITY
Self test may be accomplished using a wraparound
mode. This is done by switching TX DATA and TX
DATA through external multiplexers into RX DATA
and RX DATA. During this operation the transceiver
must be inhibited to avoid extraneous transmission
on the bus.
Decoder Operation
RECEIVER DATA (RX DATA) and (RX DATA)
Inputs from a compatible transceiver in
complementary serial biphase form.
RECEIVER BUSY (RCVR BUSY)
Outputs status of received information when data is
being transferred into the receiver data buffer
registers after a valid sync has been received. The
line will go high when busy and remain so until the
completion of the receive cycle.
RECEIVER SYNC TYPE
Outputs the sync field polarity of each input word
and is valid when (RCVR BUSY) signal is high. A
high indicates command or status sync; a low
indicates data sync.
VALID WORD
Transitions from high to low after receipt of a valid
sync, 16 data bits and an odd parity bit. Transition
back to high indicates that data is now available in
the three state output register.
SYSTEM ACKNOWLEDGE (SACK)
An input transistion from high to low enables
readout transfer from output registers onto the
parallel data output lines. Duration should be
approximately 2sec. The leading edge transition
resets VALID WORD and VU INT to high, permitting
a new receive cycle.
VALID ADDRESS (VU INT)
Output goes low only upon validation of input word
and recognition of its internal terminal address.
COMMAND SYNC CLEAR:
This input low must be provided 2sec after each
RECEIVER SYNC TYPE low to high transition, and
must be no wider than 1sec.
Encoder Operation
OUTPUT SELECT (OSEL)
Logic low transfers input data into internal buffer
registers for processing.
SYNC SELECT
Prior to initiation of a transmission this line should
be set high. Retention of high establishes a
command or status sync and a low will produce a
data sync. The line should be brought low prior to
the high to low transition of the TRANSMITTER
BUSY line. For successive transmissions refer to
the Transmitter Section Timing Diagram.
ENCODER ENABLE
A logic high starts an encoder cycle. Retention of
high permits successive transmissions, which can
be avoided by transitioning, to low at least lsec
before XMTR BUSY transition.
TRANSMITTER BUSY (XMTR BUSY)
High is busy indicating that data is being shifted
from the input data buffer to the encoder.
TRANSMIT DATA (TX DATA) and (TX DATA)
Output from the encoder in complementary serial
form. Positive and negative excursions represent
digital "1"s and "0"s.
Aeroflex Circuit Technology
SCD2412 REV C 10/19/98 Plainview NY (516) 694-6700
5
1MHZ CLOCK
POWER ON CLEAR
POC (INPUT)
RX DATA (INPUT)
RX DATA (INPUT)
RECEIVER SYNC TYPE
RECEIVER BUSY
VALID WORD
VU INT (OUTPUT)
VALID ADDRESS
SACK (INPUT)
SYSTEM ACKNOWLEDGE
COMMAND SYNC
CLEAR (INPUT)
1MHZ CLOCK
BIT TIMES
POWER ON CLEAR
POC (INPUT)
OUTPUT SELECT
(INPUT)
SYNC SELECT
(INPUT)
ENCODER ENABLE
(INPUT)
XMTR BUSY
(OUTPUT)
TX DATA (OUTPUT)
TX DATA (OUTPUT)
(OUTPUT)
(OUTPUT)
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20
1
2
3
4
5
6
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20
1
2
3
4
Figure 3 TRANSMITTER SECTION TIMING FOR ENCODE OPERATION
Figure 2 RECEIVER SECTION TIMING FOR DECODE OPERATION
500ns NOM
500ns NOM
50ns MIN to 20s MAX
100ns
MIN
4s
NOM
5 BIT
ADDRESS
5s
NOM
DATA
SYNC
COMMAND
SYNC
BIT TIMES
(OUTPUT)
25ns MIN to 1s MAX
2
S
DO NOT CUE FROM VALID WORD
Note: A Command Sync Clear must be provided for
every Receiver Sync Type low to high transition.
100 ns MIN
1s NOM 100ns MIN
(OR DELAY)
1.0 s MIN
BRING LOW NO LATER THAN XMTR BUSY HIGH TO LOW
Drop Enable 1s MIN Before
XMTR Busy To Stop Next Word
16s NOM
DATA
SYNC
COMMAND
SYNC
1s NOM
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
2
3
4
1
5 - - - -
4s
NOM
16s NOM
16s NOM
16s NOM
16s NOM
5s
NOM
2s NOM
2s NOM
COMMAND SYNC
DATA SYNC
DON'T CARE
0.5 s MAX
SEND DATA
SEND DATA
1.0 s MIN
3.5s
NOM
TAKE DATA
TAKE DATA
16s NOM
Aeroflex Circuit Technology
SCD2412 REV C 10/19/98 Plainview NY (516) 694-6700
6
Package Pin Out Description By Pin - ACT2412
Pin #
Function
Input / Output
1 - 16
Parallel Data (DB0 - DB15)
Both
17
No Connection
18
+5VDC
19
GND
20
DSC Out
Output
21
Power On Clear (POC)
Input
22
Transmitter Busy (XMTR BUSY)
Output
23
Receiver Busy (RCVR BUSY)
Output
24
Sync Select
Input
25
Encoder Enable
Input
26
System Acknowledge (SACK)
Input
27
2 MHZ Out
Output
28
Output Select (OSEL)
Input
29
No Connection
30
Transmitter Data (TX DATA)
Output
31
Transmitter Data (TX DATA)
Output
32
Receiver Data (RX DATA)
Input
33
Receiver Data (RX DATA)
Input
34
Valid Word
Output
35
Clock 2 Input (12 MHz)
Input
36
Clock 1 Output (12 MHz)
Output
37
Clock 1 Input (12 MHz)
Input
38
Clock Select (CK SEL)
Logic "1" = Clock 1 Select
Logic "0" = Clock 2 Select
Input
39
Valid Address (VU INT)
Output
40
No Connection
41
Command Sync Clear
Input
42
Receive Sync Type
Output
43
Case GND
44 - 48
Own Address (B0 = MSB to B4)
Input
Aeroflex Circuit Technology
SCD2412 REV C 10/19/98 Plainview NY (516) 694-6700
7
Ordering Information
Model Number
Package
ARX2412
1.74" x 1.14" Metal Plug In
C I R C U I T T E C H N O L O G Y
Specifications subject to change without notice.
Aeroflex Circuit Technology
35 South Service Road
Plainview New York 11830
Telephone: (516) 694-6700
FAX: (516) 694-6715
Toll Free Inquiries: 1-(800)THE-1553
16
1
25
40
48
24
17
41
.018 DIA TYP
.200 MIN
.002
1.740
1.500
1.140
.900
.450 REF
.100 TYP
.050 RADIUS MAX TYP
.060 RADIUS 4 PLACES
.210 MAX
Plug-In Package Outline