ChipFind - документация

Электронный компонент: Series D2W

Скачать:  PDF   ZIP
Triac Output
Printed Circuit Board Mount
Internal Snubber
Zero Voltage Switching
FastFax Document No. 116
SERIES D2W 032698, PAGE 1 OF 1
Series D2W
2-3.5 Amps 120/240 Vac AC Output SIP
The D2W Series features an epoxy-
coated package that provides excep-
tional environmental protection.
Pinouts are compatible with Series 6
and OAC type I/O modules.
Manufactured in Crydom's ISO 9002
Certified facility for optimum product
performance and reliability.
M O D E L N O .
D2W202F
D2W203F
D2W203F-11
INPUT SPECIFICATIONS
Control Voltage Range
3-32 Vdc
3-32 Vdc
3-32 Vdc
Nominal Input Impedance
1500 Ohm
1500 Ohm
1500 Ohm
Typical Input Current @ 5 Vdc
3.0 mAdc
3.0 mAdc
3.0 mAdc
Must Turn On Voltage
3.0 Vdc
3.0 Vdc
3.0 Vdc
Must Turn Off Voltage
1.0 Vdc
1.0 Vdc
1.0 Vdc
OUTPUT SPECIFICATIONS
Operating Voltage Range (47-63 Hz)
24-280 Vrms
24-280 Vrms
24-280 Vrms
Load Current Range
.06-2.0 Arms
.06-3.0 Arms
.06-3.5 Arms
Transient Over-Voltage
600 Vpk
600 Vpk
600 Vpk
Max. Surge Current, (16.6ms)
28 Apk
70 Apk
80 Apk
Min. Off-State dv/dt @ Max. Rated Voltage
200 V/sec
200 V/sec
200 V/sec
Max.Off-State Leakage @ Rated Voltage
8 mArms
8 mArms
8 mArms
Max. On-State Voltage Drop @ Rated Current
1.4 Vpk
1.4 Vpk
1.4 Vpk
Max.Turn-On Time
1/2 cycle
1/2 cycle
1/2 cycle
Max. Turn-Off TIme
1/2 cycle
1/2 cycle
1/2 cycle
Power Factor (Min.) WIth Max. Load
0.5
0.5
0.5
GENERAL SPECIFICATIONS
Dielectric Strength
4000 Vrms
Insulation Resistance (Min.) @ 500 Vdc
10
9
Ohm
Max. Capacitance
10 pF
A
mbient Operating Temperature Range
-30 to 80C
Ambient Storage Temperature Range
-30 to 125C
MECHANICAL SPECIFICATIONS
Weight: (typical)
0.6 oz. (17 g)
Encapsulation:
Thermally Conductive Epoxy
1
2
3
4
1.18
MAX.
(29.9)
.700
(17.8)
1.100
(27.9)
1.7 MAX.
(43.2)
.050
TYP.
(1.3)
CONTROL
LOAD
.47 MAX.
(11.9)
.12
(3.0)
.040 (1.0) DIA.
(4 PLACES)
.200
(5.1)
.39 TYP.
(9.9)
G E N E R A L N O T E S
All parameters at 25C unless otherwise specified.
Dielectric and insulation resistance are measured between input and output.
Off-State dv/dt test method per EIA/NARM standard RS-443.
All dimensions are in inches (millimeters)
APPROVALS
UL
E116950
CSA
LR81689
2.5
2.0
1.5
1.0
0.5
20
40
60
80
AMBIENT TEMPERTURE (C)
LOAD CURRENT (AMPS)
3.5
3.0
Max. Load Current vs. Temp.
D2W203F
D2W203F-11
D2W202F
CURRENT DERATING CURVE
1998 CRYDOM CORP, Specifications subject to change without notice.
PIN 1: AC LOAD
PIN 2: AC LOAD
PIN 3: +DC CONTROL
PIN 4: -DC CONTROL
For recommended applications and more information contact:
USA: (800) 8 CRYDOM (800) 827-9366 (619) 715-7200 fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 fax (49)(0)6874 182585 Crydom GmbH,
Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany e-mail: vertrieb@crydom.com