ChipFind - документация

Электронный компонент: TLE6250

Скачать:  PDF   ZIP
Data Sheet Version 3.4
1
2002-10-08
CAN-Transceiver
TLE 6250
TLE 6250 V33
Final Data Sheet
P-DSO-8-3
Features
CAN data transmission rate up to 1 MBaud
Suitable for 12 V and 24 V applications
Excellent EMC performance (very high immunity and
very low emission)
Version for 5 V and 3.3 V micro controllers
Bus pins are short circuit proof to ground and battery
voltage
Over-temperature protection
Very wide temperature range (- 40C up to 150C)
Description
The CAN-transceiver TLE 6250 is a monolithic integrated circuit that is available as bare
die as well as in a P-DSO-8-3 package. The IC is optimized for high speed differential
mode data transmission in automotive and industrial applications and is compatible to
ISO/DIS 11898 (see page 12 and 20). It works as an interface between the CAN protocol
controller and the physical differential bus in both, 12 V and 24 V systems.
Note:
There are two versions available: one for 5 V logic and the other one for 3.3 V logic
requiring additional supply via the V
33V
pin. The IC can be set to stand-by mode via an
control input. In addition the 5 V-version offers a receive only mode feature to support
diagnostic functions.
The IC is based on the Smart Power Technology SPT
which allows bipolar and CMOS
control circuitry in accordance with DMOS power devices existing on the same
monolithic circuit. The TLE 6250 is designed to withstand the severe conditions of
automotive applications and provides excellent EMC performance.
Type
Ordering Code
Package
TLE 6250 G
Q67006-A9427
P-DSO-8-3
TLE 6250 C
Q67000-A9594
(chip)
TLE 6250 G V33
Q67006-A9523
P-DSO-8-3
TLE 6250 C V33
Q67000-A9538
(chip)
TLE 6250
TLE 6250 V33
Data Sheet Version 3.4
2
2002-10-08
Figure 1
Pin Configuration (top view)
Pin Definitions and Functions
Pin No.
Symbol Function
1
TxD
CAN transmit data input; 20 k
pull up, LOW in dominant state
2
GND
Ground;
3
V
CC
5 V Supply;
4
RxD
CAN receive data output; LOW in dominant state,
integrated pull up
5
RM
Receive-only input; (5 V-version), 20 k
pull up, set low to
activate RxD-only mode
V
33V
Logic supply; (3.3 V-version) 3.3 V OR 5V microcontroller logic
supply can be connected here! The digital I/Os of the TLE6250V33
adopt to the connected microcontroller logic supply at V
33V
6
CANL
Low line input; LOW in dominant state
7
CANH
High line output; HIGH in dominant state
8
INH
Control input; 20 k
pull, set LOW for normal mode
INH
GND
RxD
TxD
CANL
V
CC
RM
CANH
8
5
6
7
1
4
3
2
P-DSO-8-3
TLE 6250 G
INH
GND
RxD
TxD
CANL
V
CC
V
33V
CANH
8
5
6
7
1
4
3
2
P-DSO-8-3
TLE 6250 GV33
Data Sheet Version 3.4
3
2002-10-08
TLE 6250
TLE 6250 V33
Functional Block Diagram
Figure 2
Block Diagram TLE 6250 G
AEB02922
Stage
Output
Temp.-
Protection
Driver
=
Mode Control
Receiver
TLE 6250 G
7
6
CANH
CANL
GND
2
3
CC
V
1
TxD
8
5
4
INH
RM
RxD
TLE 6250
TLE 6250 V33
Data Sheet Version 3.4
4
2002-10-08
Figure 3
Block Diagram TLE 6250 G V33
AEB02923
Stage
Output
Temp.-
Protection
Driver
=
Mode Control
Receiver
TLE 6250 G V33
7
6
CANH
CANL
GND
2
3
CC
V
1
TxD
8
4
INH
RxD
5
V
3.3 V
Data Sheet Version 3.4
5
2002-10-08
TLE 6250
TLE 6250 V33
Application Information
Figure 4
Mode State Diagram
Both, the TLE 6250 G as well as the TLE 6250 C offer three different operation modes
(see Figure 4), controlled by the INH and RM pin for the TLE6250 and only by the INH
pin for the 6250 V33. In the normal mode the device is able to receive and to transmit
messages whereas in the receive-only mode signals at the TxD input are not transmitted
to the CAN bus. The receive-only mode can be used for diagnostic purposes as well as
to prevent the bus being blocked by a faulty permanent dominant TxD input signal. The
stand-by mode is a low power mode that disables both, the receiver as well as the
transmitter. For the TLE 6250 G V33 and TLE 6250 C V33 the receive only mode
feature is not available. The inhibit feature for this versions works in the same way as for
the 5V versions.
In case the receive-only feature is not used the RM pin has to be left open. When the
stand-by mode is not used the INH pin has to be connected to ground level in order to
switch the TLE 6250 in normal mode.
AED02924
Normal Mode
INH = 0
RM = 1
INH = 0
Receive-only Mode
RM = 0
INH = 1
Stand-by Mode
RM = 0 / 1
INH = 0
and RM = 0
INH = 1
INH = 1
INH = 0
and RM = 1
RM = 0
RM = 1
Normal Mode
INH = 0
Stand-by
Mode
INH = 1
INH=1
INH=0
5V Version