ChipFind - документация

Электронный компонент: TRAC-S2

Скачать:  PDF   ZIP
DEVICE DESCRIPTION
The TRAC family of Field Programmable
Analog Devices offers an integrated path from
signal processing problems to working silicon
solutions - i n minutes! The Totally
Reconfigurable Analog Circuit is a highly
flexible single chip solution to the signal
processing problems found in many markets.
Introducing a Top-Down, Structured design
disci pl ine, TRAC enables rapid
implementation, prototyping and product
release. Rather than working at the component
level, TRAC champions the Computational
Approach, providing designers with benefits
formerly associated only with programmable
digital devices. TRAC brings a truly integrated
Signal Processing problem solving process,
offering a path to Custom Silicon for higher
volume users.
TRAC devices have to be loaded with program
data at power-up and run from a split 5V
supply. By integrating the loading interface
ci rcuitry, vol tage regulation, supply
monitoring and thermal protection, the TRAC
support circuit (TRAC-S2) further simplifies
circuit integration and interface with memory
devices.
An adjustable frequency oscillator clocks
program data out of a serial output memory
device and into any number of cascaded TRAC
devices. By monitoring the bit stream pattern,
TRAC-S2 can sense when loading is complete
and stop clocking automatically.
An adjustable `rail-splitter' generates the
ground supply rail, and the supply monitoring
function initiates program load on power-up,
and after power failure or serious fluctuation.
Thermal shutdown further protects the device
against overheating.
FEATURES & BENEFITS
Makes designing TRAC circuits easier,
production prototyping quicker
Reduces component count and
manufacturing costs
Enables simple connection of a serial output
EEPROM or other memory device to TRAC
Compatible with current and future TRAC
devices
Automatic program loading at power-up
Supply monitor function reloads program
after power failure or fluctuation
Frequency of on-chip oscillator user-defined
Senses number of cascaded TRAC devices
automatically
Automatically stops clocking when program
loading complete
Simplifies generation of TRAC supply
voltages
Ground voltage user defined
Thermal shutdown function protects against
overloading due to circuit failures
Full industrial temperature range
ORDERING INFORMATION
PART NUMBER
PACKAGE
PART
MARK
TRAC-S2Q16
QSOP16
TRAC-S2
TRAC
SUPPORT CIRCUIT
ISSUE 1 - JANUARY 2000
TRAC-S2
1
ABSOLUTE MAXIMUM RATINGS
Supply Voltage
0V to +7V
Supply Current
50mA
Operating Temperature Range
-40C to 85C
Storage Temperature Range
-55C to 125C
ELECTRICAL CHARACTERISTICS
Test Conditions: Temperature=25C, V
DD
=5V, V
SS
=0V, CLCR_IN=0V,
100nF between AGND_OUT and V
SS
, unless otherwise stated.
PARAMETER
CONDITIONS
MIN
TYPICAL
MAX
Supply Voltage Operating Range
4.8V
5.0V
5.2V
Supply Current
Standby (CLCR_IN = 0V)
Clocking (CLCR_IN = 5V)
1.5mA
2.9mA
1.9mA
3.7mA
2.8mA
5.5mA
RAIL SPLITTER
SETV(Input Current)
SETV = 2.50V
50nA
200nA
AGND_OUT
(Output Voltage)
SETV = 2.50V (No Load)
SETV = 2.0V (No Load)
2.49V
1.99V
2.50V
2.00V
2.51V
2.01V
AGND_OUT
(Output Voltage)
SETV = 2.50V; I
SINK
= 20mA
SETV = 2.50V; I
SOURCE
= 20mA
AGND_OUT
- 0.010V
AGND_OUT
+ 0.010V
SUPPLY MONITOR
RESET_OUT
(Threshold Voltage)
High State Output (VDD increasing)
Low State Output (VDD decreasing)
4.35V
4.35V
4.67V
4.65V
4.75V
4.75V
RESET_OUT (Hysteresis)
0.01V
0.02V
0.08V
RESET_OUT
(Onstate output sink current)
VDD = RESET_OUT = 4V
0.14mA
RESET_OUT
(Offstate output current)
VDD = RESET_OUT = 5V
0.18mA
PROPAGATION DELAY
VDD step from 5.0V to 4.0V
1
S
PROGRAMMING LOGIC
CLK_OUT
(Frequency)
2.2nF between CAP and V
SS
CLCR_IN = 5V
7kHz
10kHz
15kHz
CLK_OUT
(Max Programming Frequency)
47pF between CAP and V
SS
CLCR_IN = 5V
200kHz
CLK_OUT
(High output voltage)
2.2nF between CAP and V
SS
CLCR_IN = 5V
3.90V
4.10V
4.50V
NOT CLK_OUT(Frequency)
2.2nF between CAP and V
SS
CLCR_IN = 5V
7kHz
10kHz
15kHz
NOT CLK_OUT(High output
voltage)
2.2nF between CAP and V
SS
CLCR_IN = 5V
4.00V
4.20V
4.60V
TRAC-S2
2
ELECTRICAL CHARACTERISTICS
Test Conditions: Temperature=25C, V
DD
=5V, V
SS
=0V, CLCR_IN=0V,
100nF between AGND_OUT and V
SS
, unless otherwise stated.
DATA_OUT(Frequency)
2.2nF between CAP and V
SS
CLCR_IN = 5V
1.7kHz
2.5kHz
4.0kHz
DATA_OUT(High output
voltage)
2.2nF between CAP and V
SS
CLCR_IN = 5V
3.90V
4.10V
4.50V
SELECT
(Output Voltage)
2.2nF between CAP and V
SS
CLCR_IN = 5V
4.8V
4.99V
5.00V
DESCRIPTION OF PIN FUNCTIONS
Inputs
SETV
Defines the AGND_OUT voltage. Normally set by potential divider
CLCR_IN
Active high to enable clock
CAP
Capacitor to V
SS
sets clock frequency
Outputs
AGND_OUT
Analog Ground. Able to source and sink current
SELECT
Active high when CLCR_IN is logic high. Enables memory device
CLK_OUT
Fed to EEPROM clock input
NOT CLK_OUT
Fed to TRAC clock input
DATA_OUT
CLK_OUT divided by four. Fed to serial output memory device
RESET_OUT
Reset for TRAC Support Circuit and TRAC devices
General notes for the TRAC Support Circuit
An on-chip oscillator produces the output CLK_OUT and NOT CLK_OUT. CLCR_IN must be logic high
(V
DD
) to activate CLK_OUT and NOT CLK_OUT
The CLK_OUT output frequency is divided by four to give the DATA_OUT output. Therefore CLCR_IN
must be logic high (V
DD
) to activate DATA_OUT
For AGND_OUT stability under load, a 100nF capacitor is required between AGND_OUT and V
SS
TRAC-S2
3
TRAC-S2
4
TRAC-S2
5
TRAC-S2
Description of the TRAC Support Circuit
1) Rail Splitter
This section provides the analog ground rail between the 5V supply. An external potential divider
can be connected to the SETV pin which enables AGND_OUT to be set to the desired potential. The
output stage of the rail splitter has been designed to provide power capabilities for 4 TRAC devices
and accompanying circuitry. The circuit has low output resistance enabling a drive capability of +/-
20mA.
2) Supply Monitor
This section utilises the precision ZSM560 supply monitor design. The RESET_OUT provides a signal
to reset all the devices included in the programming and operation of TRAC . This ensures that all
devices are switched on and off simultaneously.
3) Programming Logic
This section provides TRAC and memory with the signals required for programming. The clock is
generated on chip, with the frequency set by an external capacitor. The DATA_OUT signal is generated
by dividing the clock frequency by 4. This provides the code to initialise an EEPROM and prompt it to
output data. The SELECT pin enables EEPROM chip select.
This section also takes an input signal from the final TRAC device, CLCR_IN. This signal is normally
`high' and goes `low' when programming is complete, and is used to terminate the CLK_OUT and
DATA_OUT signals.
BLOCK DIAGRAM
6
APPLICATION CIRCUIT
Connections between the support circuit, the EEPROM and the TRAC device are shown above.
For a more detailed explanation of the circuit see the application note AN27, "How to use the TRAC
support chip". This also shows the circuit required to program multiple TRAC devices.
LIST OF COMPATIBLE MEMORY DEVICES
ST9346CB1 (SGS-Thomson)
93LC46B (Microchip)
NM92C46 (National Semiconductor)
TRAC-S2
7
PACKAGE DIMENSIONS
PIN No.1
IDENTIFICATION
RECESS
FOR PIN 1
A
B
D
J
E
F
G
C
K
QSOP16
PIN
Millimetres
Inches
MIN
MAX
MIN
MAX
A
4.80
4.98
0.189
0.196
B
0.635
0.025 NOM
C
0.177
0.267
0.007
0.011
D
0.20
0.30
0.008
0.012
E
3.81
3.99
0.15
0.157
F
1.35
1.75
0.053
0.069
G
0.10
0.25
0.004
0.01
J
5.79
6.20
0.228
0.244
K
0
8
0
8
TRAC-S2
Zetex plc.
Fields New Road, Chadderton, Oldham, OL9-8NP, United Kingdom.
Telephone: (44)161 622 4422 (Sales), (44)161 622 4444 (General Enquiries)
Fax: (44)161 622 4420
Zetex GmbH
Zetex Inc.
Zetex (Asia) Ltd.
These are supported by
Streitfeldstrae 19
47 Mall Drive, Unit 4
3510 Metroplaza, Tower 2
agents and distributors in
D-81673 Mnchen
Commack NY 11725
Hing Fong Road,
major countries world-wide
Germany
USA
Kwai Fong, Hong Kong
Zetex plc 2000
Telefon: (49) 89 45 49 49 0
Telephone: (631) 543-7100
Telephone:(852) 26100 611
Fax: (49) 89 45 49 49 49
Fax: (631) 864-7630
Fax: (852) 24250 494
Internet:http://www.zetex.com
This publication is issued to provide outline information only which (unless agreed by the Company in writing) may not be used, applied
or reproduced for any purpose or form part of any order or contract or be regarded as a representation relating to the products or
services concerned. The Company reserves the right to alter without notice the specification, design, price or conditions of supply of
any product or service.
8